60227 IEC 53 Copper Conductor PVC Insulated Flexible wire RVV electric cable 4x0.75mm2 1. Flexible wire RVV electric cable 4x0.75mm2 Appliation cables used for communication system, its rated voltage should be at least equal to the system of nominal voltage, In dc system, nominal voltage should not greater than 1.5 times of rated voltage, System allows more than nominal voltage working voltage by 10%. 2. Flexible wire RVV electric cable 4x0.75mm2 Product Standard 60227 IEC 53 GB/T5023-2008; JB8734-1998 (1)cables long-term allowed no more than 70°c, BV - 90 shall not exceed 90  Celsius temperature , the installation should not below 0°c  Celsius temperature . (2) cable permissible min. bending radius: less than 25 mm of exterior cable should be no less than 4 times of cable diameter, if for 25 millimeters, wire bending radius should not less than 6 times of cable diameter. (3) wire and cable length of knitting or into the dish for 100 meters, length error of 0.5 meters (4) RV - 90 long-term allowed no more than 90 °c  4. Flexible wire RVV electric cable 4x0.75mm2 Model and name Sectional Area Conductor Construction Insulation Thickness Sheath Thickness Overall Diameter Weight Appr. Max Conductor Resistance @ 20°C Min Insulation Resistance @ 70°C Ampacity in Free Air 1.18 years manufacturing experience 2.Professional international trade team 3.Delivery on time 4.Factory low price and high quality based on advanced technology and high work efficiency 60227 IEC 53 Copper Conductor PVC Insulated Flexible wire RVV electric cable 4x0.75mm2 1. Flexible wire RVV electric cable 4x0.75mm2 Appliation cables used for communication system, its rated voltage should be at least equal to the system of nominal voltage, In dc system, nominal voltage should not greater than 1.5 times of rated voltage, System allows more than nominal voltage working voltage by 10%. 2. Flexible wire RVV electric cable 4x0.75mm2 Product Standard 60227 IEC 53 GB/T5023-2008; JB8734-1998 (1)cables long-term allowed no more than 70°c, BV - 90 shall not exceed 90  Celsius temperature , the installation should not below 0°c  Celsius temperature . (2) cable permissible min. bending radius: less than 25 mm of exterior cable should be no less than 4 times of cable diameter, if for 25 millimeters, wire bending radius should not less than 6 times of cable diameter. (3) wire and cable length of knitting or into the dish for 100 meters, length error of 0.5 meters (4) RV - 90 long-term allowed no more than 90 °c  4. Flexible wire RVV electric cable 4x0.75mm2 Model and name Sectional Area Conductor Construction Insulation Thickness Sheath Thickness Overall Diameter Weight Appr. Max Conductor Resistance @ 20°C Min Insulation Resistance @ 70°C Ampacity in Free Air Lithium Battery Cr14250,Lithium Primary Cylindrical Battery,Laser Sight Lithium Battery,Laser Sight Battery Cr14250 Jiangmen Hongli Energy Co.ltd , https://www.honglienergy.com
Â
3. Flexible wire RVV electric cable 4x0.75mm2 Service Characteristic
mm2
No.
mm
mm
mm
mm
kg/km
Ω/km
MΩ.km
A
2×0.75
24
0.2
0.6
0.8
6.4
58.6
26
0.011
12
2×1.0
32
0.2
0.6
0.8
6.8
66.7
19.5
0.01
14
2×1.5
30
0.25
0.7
0.8
7.8
90.2
13.3
0.01
18
2×2.5
49
0.25
0.8
1
9.4
137.1
7.98
0.009
25
3×0.75
24
0.2
0.6
0.8
6.8
70.3
26
0.011
10
3×1.0
32
0.2
0.6
0.8
7.2
80.7
19.5
0.01
12
3×1.5
30
0.25
0.7
0.9
8.5
112.6
13.3
0.01
16
3×2.5
49
0.25
0.8
1.1
10.2
171.1
7.98
0.009
21
4×0.75
24
0.2
0.6
0.8
7.4
87.8
26
0.011
10
4×1.0
32
0.2
0.6
0.9
8.1
105.1
19.5
0.01
12
4×1.5
30
0.25
0.7
1
9.5
146.1
13.3
0.01
16
4×2.5
49
0.25
0.8
1.1
11.2
215.9
7.98
0.009
21
5×0.75
24
0.2
0.6
0.9
8.3
110.4
26
0.011
10
5×1.0
32
0.2
0.6
0.9
8.8
127.2
19.5
0.01
12
5×1.5
30
0.25
0.7
1.1
10.6
181.0
13.3
0.01
16
5×2.5
49
0.25
0.8
1.2
12.4
267.0
7.98
0.009
21
Shandong New Luxing Cable Co.,LtdÂ
Strict Quality Test ( Raw Material & Finished Cable )
CertificatesÂ
Type test reportÂ
Packaging & ShippingÂ
Contact InformationÂ
Â
Â
3. Flexible wire RVV electric cable 4x0.75mm2 Service Characteristic
mm2
No.
mm
mm
mm
mm
kg/km
Ω/km
MΩ.km
A
2×0.75
24
0.2
0.6
0.8
6.4
58.6
26
0.011
12
2×1.0
32
0.2
0.6
0.8
6.8
66.7
19.5
0.01
14
2×1.5
30
0.25
0.7
0.8
7.8
90.2
13.3
0.01
18
2×2.5
49
0.25
0.8
1
9.4
137.1
7.98
0.009
25
3×0.75
24
0.2
0.6
0.8
6.8
70.3
26
0.011
10
3×1.0
32
0.2
0.6
0.8
7.2
80.7
19.5
0.01
12
3×1.5
30
0.25
0.7
0.9
8.5
112.6
13.3
0.01
16
3×2.5
49
0.25
0.8
1.1
10.2
171.1
7.98
0.009
21
4×0.75
24
0.2
0.6
0.8
7.4
87.8
26
0.011
10
4×1.0
32
0.2
0.6
0.9
8.1Lithium Battery CR14250
60227 IEC 53 Copper Conductor PVC Insulated Flexible Wire Rvv Electric Cable 4X0.75mm2
Model NO.: Flexible wire RVV electric cable 4x0.75mm2
Material Shape: Round Wire
Range of Application: Lsoh / Flame Retardant
Certification: ISO9001, CE, UL, CCC, RoHS, VDE
Brand: Chang Qing Teng
Item Name: Flexible Wire Rvv Electric Cable 4X0.75mm2
Rated Voltage: 300/500 V 450/750V
Conductor: Flexible Copper Conductor
Insulation: PVC
Sheath: PVC
Standard: IEC 60227
MOQ: 100
Delivery: 3-10 Working Days
Packaging: 100 Meter One Roll
Color Number: 2 3 4 5 6 7 8
Trademark: Luxing
Transport Package: 100 Meter Packed in One Roll
Specification: Roll according to different size
Origin: Shandong, China
HS Code: 8544492100
Model NO.: Flexible wire RVV electric cable 4x0.75mm2
Material Shape: Round Wire
Range of Application: Lsoh / Flame Retardant
Certification: ISO9001, CE, UL, CCC, RoHS, VDE
Brand: Chang Qing Teng
Item Name: Flexible Wire Rvv Electric Cable 4X0.75mm2
Rated Voltage: 300/500 V 450/750V
Conductor: Flexible Copper Conductor
Insulation: PVC
Sheath: PVC
Standard: IEC 60227
MOQ: 100
Delivery: 3-10 Working Days
Packaging: 100 Meter One Roll
Color Number: 2 3 4 5 6 7 8
Trademark: Luxing
Transport Package: 100 Meter Packed in One Roll
Specification: Roll according to different size
Origin: Shandong, China
HS Code: 8544492100