ABC-Aerial Bundle Cable/Service Drop Line Aerial Bundle Cable,Single Core Cable ,Control Cable ,Underground Cable Electric Wire & Cable Co., Ltd. , http://www.nbpowercable.com
Original Meanwell CLG-60 Series Single Output Waterproof IP67 LED Driver Features:
1. Universal AC input / Full range (up to 295VAC)
2. Built-in active PFC function
3. High efficiency up to 89%
4. Protections: Short circuit / Over current / Over voltage / Over temperature
5. Cooling by free air convection
6. IP67 design for indoor or outdoor installations
7. Class 2 power unit
8. Pass LPS
9. 100% full load burn-in test
10. High reliability
11. Suitable for LED lighting and moving sign applications (Note.2)
12. Compliance to worldwide safety regulations for lighting
13. Suitable for dry / damp / wet locations
14. 3 years warranty
Original Meanwell CLG-60 Series Single Output Waterproof IP67 LED Driver Specifications:
Â
MODEL
CLG-60-12
CLG-60-15
CLG-60-20
CLG-60-24
CLG-60-27
CLG-60-36
CLG-60-48
OUTPUT
DC VOLTAGE
12V
15V
20V
24V
27V
36V
48V
CONSTANT CURRENT REGION Note.5
8.4 ~ 12V
10.5 ~ 15V
14 ~ 20V
16.8 ~ 24V
18.9 ~ 27V
25.2 ~ 36V
33.6 ~ 48V
RATED CURRENT
5A
4A
3A
2.5A
2.3A
1.7A
1.3A
CURRENT RANGE
0 ~ 5A
0 ~ 4A
0 ~ 3A
0 ~ 2.5A
0 ~ 2.3A
0 ~ 1.7A
0 ~ 1.3A
RATED POWER
60W
60W
60W
60W
62.1W
61.2W
62.4W
RIPPLE & NOISE (max.) Note.2
2Vp-p
2.4Vp-p
1.8Vp-p
2.7Vp-p
2.7Vp-p
3.6Vp-p
4.6Vp-p
VOLTAGE ADJ. RANGE
11.5 ~ 13V
14.5 ~ 16.2V
19.5 ~ 22V
24 ~ 26V
25 ~ 30V
32.5 ~ 39V
43.6 ~ 51.8V
Fixed can be modified between the range above
CURRENT ADJ. RANGE
Fixed. Can be modified between 3% ~ -25% rated output current
VOLTAGE TOLERANCE Note.3
±10%
LINE REGULATION
±3.0%
LOAD REGULATION
±5.0%
SETUP TIME
500ms / 230VAC 3000ms / 115VAC at full load
INPUT
VOLTAGE RANGEÂ Â Â Â Â Â Â Note.4
90 ~ 295VACÂ Â Â 127 ~ 417VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.94/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
TOTAL HARMONIC DISTORTION
THD< 20% when output loading>=70% at 115VAC/230VAC input and output loading>=75% at 277VAC input
EFFICIENCY (Typ.)
85%
86%
87.5%
87%
88%
89%
89%
AC CURRENT (Typ.)
0.8A/115VACÂ Â Â 0.4A/230VACÂ Â Â 0.3A/277VAC
INRUSH CURRENT(Typ.)
COLD START 35A(twidth=45μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A
32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT
<0.75mA / 240VAC
PROTECTION
OVER CURRENT
95 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
13.8 ~ 16V
17.5 ~ 21V
23 ~ 28V
28 ~ 32V
31 ~ 35V
41 ~ 46V
54 ~ 60V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT
WORKING TEMP.
-30 ~ +70ºC (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +80ºC, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/ºC (0 ~ 50ºC)
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY &
EMCSAFETY STANDARDS
UL879, UL8750, UL1310, TUV EN61347-1, EN61347-2-13 independent, CAN/CSA C22.2 No. 223-M91(except for 48V),
CSA C22.2 No. 250.0-08(except for 48V), CSA C22.2 No. 207-M89(except for 48V), IP67, J61347-1, J61347-2-13 approved
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P:100M Ohms / 500VDC / 25ºC/ 70% RH
EMC EMISSION
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C (>=75% load) ; EN61000-3-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547, light industry level (surge 4KV), criteria A
OTHERS
MTBF
495.7Khrs min. MIL-HDBK-217F (25ºC)
DIMENSION
195.6*61.5*38.8mm (L*W*H)
PACKING
0.86Kg; 16pcs/14.8Kg/0.54CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Please refer to "DRIVING METHODS OF LED MODULE".
6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
7. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
8. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.
Â
Â