Describe the common faults and treatment methods of the sliding line

First, the sliding line is powered off
A sliding co ntact line power,
The main reason: the brush climbs the slope in the pipe; the brush is seriously worn and cannot touch the conductor; the conductor joint is not flat; the single collector is used; the rail joint is loose.
The main reason: brush in the co nduit climbing; brush wear serious, can not touch the conductor; the co nductor joint roughness; single collector;
Treatment method: detect whether the current collector is seriously worn, replace the current collector; replace the brush; re-adjust the connection node; use the double brush collector; re-adjust the tightening connection screw.
Treatment methods: detection of collector is badly worn; replace the collector; Replacement Brush; re adjust the connection; with double brush collector; re adjust, tighten the screw connection.
Second, the guide rail deformation, the collector movement is blocked
Two, rail deformation, collector movement blocked
The main reason: the ambient temperature is too high; the pitch of the lifting rack is large or loose.
The main reason: the high ambient temperature; lifting rack spacing or loose.
Treatment method: Partially use heat insulation board, outdoor add sun visor; increase the number of sliding line lifting racks, correct the catheter, and tighten the screws.
Processing method: partial use of insulation board, outdoor and visor; increase the sliding co ntact wire rack number provided, correct catheter, and tighten the screws.
Third, the sliding line is large when working
Three, work of sliding co ntact line shaking big
The main reason: the fork can not absorb the transmission error; the straight line of the guide rail is poor; the hanger is loose.
The main reason: fork cannot absorb transmission error; rail line straightness deviation; lifting rack loose.
Treatment method: Correct the tractor so that it can absorb the transmission error freely; adjust the straightness of the guide rail; tighten the lifting bracket screw.
Treatment methods: fixed traction device, which can free free absorption, transmission error; the adjusting guide rail straightness; tighten screws lifting rack.
Fourth, the brush wears fast
Four, brush wear quickly
The main reason: the joint is not flat; the current carrying capacity is too large; the spring pressure is large.
The main reason: joint roughness; carrying capacity is t [industrial electrical network-cnelc] oo large; the spring pressure.
Treatment method: reconnect the rails as required; increase the number of collectors; replace and correct the spring pressure.
Processing method: according to the requirement of re co nnected with the guide rail; increase the collector number; replacement, correction spring pressure.
Fifth, the side of the brush is scratched
Five, brush side abrasion
The main reason: the brush wear, the slip line collector is not correct; the fork side force transmission of the tractor is too large.
The main reason: brush wear, sliding touch line collector for it; the shifting fork side force of the tractor transmission is too large.
Treatment: Replace and correct the spring pressure; replace the traction fork or correct the tractor fork.
Processing method: replacement, correction spring pressure; replace the traction fork or modified tractor fork.
Six, there are sparks in the guide rail
Six, rail spark
The main reason: poor contact between the brush surface and the guide rail.
The main reason: brush the surface in co ntact with the rail side.
Treatment method: Detect the rail joint and properly wear the brush to ensure 60% contact area.
Treatment methods: detecting the rail joint, appropriate running in brush to ensure 60% co ntact area.
Seven, the sliding line collectors have a large abnormal noise
Seven, the sliding co ntact line collector walking has large abnormal sound
The main reason: the current is too large; the joint is not flat.
The main reason: the current is too large; joint roughness.
Treatment method: increase the number of collectors; re-install the rail connection.
Treatment methods: increase the collector number; re install rail connection.
Eight, the sliding line collector shell scratches
Eight, the sliding co ntact line collector casing abrasion
The main reason: the deformation of the guide rail; the collector is set to be poor.
The main reason: rail deformation; collector for the poor.
Treatment method: According to fault 2, increase the clamping clamp; adjust the current collector.
Processing method: according to the fault treatment increased 2, shaping clamp; adjust the collector.

PZT Piezoelectric Cylinders/Tubes

Yuhai company develop and produce of various tube/cylinder sizes, bearing variety of electrode and metallisation configurations. The tubes is fabricated from various published and additional custom in-house Piezoelectric Material formulations for applications such as high power, sensitivity, stability needs.


https://youtu.be/uscX0htQIkg



Features


  • · Choice of metallisation (Silver, Nickel, Gold and others on request)
  • · Evaporated and chemically deposited metallisation's available
  • · Thickness/Radial frequency tuning available on request
  • · Wrap around electrode configuration
  • · Wide choice of PZT formulations




aApplications include


  • · Hydrophones
  • · Fibre optic stretcher
  • · Augmented reality
  • · Torpedo decoys
  • · Accelerometers
  • · Pressure sensors
  • · Print head transducers
  • · Oil and gas exploration
  • · Scientific equipment


Tubes

Height: 1-100mm

OD: 6-180mm

ID: 5-150mm

Wall: 0.5-15mm






Piezo Tube,Piezoelectric Tube,Piezo Electric Tube,Piezo Ceramic Tubes

Zibo Yuhai Electronic Ceramic Co., Ltd. , https://www.yhpiezo.com